On Fri, 2014-04-18 at 11:19 -0400, Cyrus Vatan wrote:
> Anyways my issue is with pins with letters for pin
> numbers failing to have rats attached to them once imported into PCB.

Note that this can only work, when the footprint's pinnumber is also
that same letter! Often footprints have decimal numbers, so you may have
to edit the footprint file if you use letters. There should be some more
information in the documentation -- unfortunately transistors are the
more difficulty elements...