ftp.delorie.com/archives/browse.cgi   search  
Mail Archives: geda-help/2016/08/03/03:28:15

X-Authentication-Warning: delorie.com: mail set sender to geda-help-bounces using -f
X-Recipient: geda-help AT delorie DOT com
X-Original-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed;
d=gmail.com; s=20120113;
h=in-reply-to:references:mime-version:content-transfer-encoding
:subject:from:date:to:message-id;
bh=bLGvV9u3u/5cGek9/DE91974Bq88BD4jEgs//DXpUPQ=;
b=tTXzyhCziZErNmZDtMEW/qDuJ+dE4B1OpARYQ+yizFdgPAjDnHtPfdyizaZHqXsagG
6eegYu1E0zGEUoxqRCrcJfxQzL+ufrw8X4m1NHyIoqQnkTuQJY0NbvOk2xoQw7QoPvAb
onBnfs/doNT59UUQMv/dK4LEN7R/K3OcM6bJBjJBoRbQvBhntUg2gFYY3P1z58qLHBI5
fLFRDZCNhVuajeu8x4F+MjdFIJRVkOleDGeloqa73kKKcj0SO1mwGFrAbLEtvjrcMkBx
jiWVQ6w4pCYIAXRRBVnh9ZkwdwOkTlH6lo3zIBDE5WCTjnd0Yxk4zcOc5tg6TQWCy1cX
F1lg==
X-Google-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed;
d=1e100.net; s=20130820;
h=x-gm-message-state:in-reply-to:references:mime-version
:content-transfer-encoding:subject:from:date:to:message-id;
bh=bLGvV9u3u/5cGek9/DE91974Bq88BD4jEgs//DXpUPQ=;
b=dC2WNSoodkyCo2iV3UPhwYzi1xfMas7PeiaFLmnwWANrQdDEWbgJwFPZeeMAngcXzc
zA5lYwyZf+1Rlv4wWDGBkiKwcJWngMGAHkSd0P9JEBmBq38FchsSkFyqljLgLr9ptb9Z
9M412tRXL5VmXgh/I/R/PNGi7oLlRPxZ9O8iEQaefiY7Xv4t2gY90Pf09z94HcoiuNsA
i/4FhI2rLjW2TkccTmRe79/ckgfQfuNfSlkoeFxESHVvsRLziqwnP19jrntP92OFKQqK
HbFZCVVYEEmQPl9InlsjJ7QdBTIcaCrJ+HopizISIXaKwYBnqwvrfHb9L74CIlglGviJ
q+/Q==
X-Gm-Message-State: AEkoousGXdqjHGp0BFHkLzxlaGhySgy5WJ1B+f8vZoceUeEOyOQnbbx0jLl/5bKyybqQUA==
X-Received: by 10.28.64.86 with SMTP id n83mr69130570wma.52.1470209273741;
Wed, 03 Aug 2016 00:27:53 -0700 (PDT)
In-Reply-To: <b7127584-363e-2903-3382-8ba0eda2c02d@prochac.sk>
References: <20160728160657 DOT 7f68f787 AT debian> <20160728174027 DOT 453b2b41 AT debian DOT olsr> <20160728192015 DOT 4fc84ce8 AT debian DOT olsr> <201607282248 DOT u6SMmTxw006065 AT envy DOT delorie DOT com> <f3e69165-857d-c541-33d1-557fc93172a4 AT prochac DOT sk> <b7127584-363e-2903-3382-8ba0eda2c02d AT prochac DOT sk>
MIME-Version: 1.0
Subject: Re: [geda-help] pcb: blind via
From: "Carlos Nieves (cnieves DOT mail AT gmail DOT com) [via geda-help AT delorie DOT com]" <geda-help AT delorie DOT com>
Date: Wed, 03 Aug 2016 09:27:51 +0200
To: geda-help AT delorie DOT com
Message-ID: <F58DF9DA-A2B3-4897-9B1A-9E740E3148A0@gmail.com>
Reply-To: geda-help AT delorie DOT com
Errors-To: nobody AT delorie DOT com
X-Mailing-List: geda-help AT delorie DOT com
X-Unsubscribes-To: listserv AT delorie DOT com


El 3 de agosto de 2016 3:31:40 CEST, "Milan Prochac (milan AT prochac DOT sk) [via geda-help AT delorie DOT com]" <geda-help AT delorie DOT com> escribió:

[Snip]

>      5a. on GUI HID (screen) vias themselves are drawn unchanged. Any 
>recommendation how to visually distinguish blind/buriad vias from 
>through-hole vias are welcome.

In other CADs, this is reported showing on screen, on top of the via, the number of the initial and end layer for that via.

E.g.: 1:2 for a layer between layers 1 and 2.

For normal vias, no numbers are shown. 

Congratulations for your work!!

Carlos