ftp.delorie.com/archives/browse.cgi   search  
Mail Archives: geda-user/2012/03/13/13:46:42

X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f
X-Recipient: geda-user AT delorie DOT com
Subject: Re: [geda-user] PCB - footprint creation
From: Stefan Salewski <mail AT ssalewski DOT de>
To: geda-user AT delorie DOT com
In-Reply-To: <CACPio-6GEfeFrJiS2xnQihQPP12CtSEnMWhWCx-Cu4ekBfsXFw@mail.gmail.com>
References:
<CACPio-6GEfeFrJiS2xnQihQPP12CtSEnMWhWCx-Cu4ekBfsXFw AT mail DOT gmail DOT com>
Date: Tue, 13 Mar 2012 18:45:52 +0100
Message-ID: <1331660752.2530.3.camel@AMD64X2.fritz.box>
Mime-Version: 1.0
X-Mailer: Evolution 2.32.3
Reply-To: geda-user AT delorie DOT com
Errors-To: nobody AT delorie DOT com
X-Mailing-List: geda-user AT delorie DOT com
X-Unsubscribes-To: listserv AT delorie DOT com

On Tue, 2012-03-13 at 09:38 -0400, Nathan Stewart wrote:

> BTW - is there a better way to deal with rats going to ground? It seems to
> want to connect them to "nearby" components when they could be a lot less
> confusing if they picked another point at ground.
> 
> Thanks

You can hide the GND rats -- Select Windows -> Nelist from menu, double
click on GND or AGND or whatever you want to hide. A * should appear at
the left. Not click on the main window with the pcb layout and press "o"
key to optimize rats. GND rats should disappear.


- Raw text -


  webmaster     delorie software   privacy  
  Copyright © 2019   by DJ Delorie     Updated Jul 2019