X-Authentication-Warning: delorie.com: mail set sender to geda-help-bounces using -f X-Recipient: geda-help AT delorie DOT com Date: Tue, 23 Feb 2016 14:09:11 +0100 From: "Smilie (smilie AT posteo DOT de) [via geda-help AT delorie DOT com]" To: geda-help AT delorie DOT com Subject: Re: [geda-help] little Question.... Message-ID: <20160223140911.022af707@debian> In-Reply-To: References: <20160222220125 DOT 1dd46469 AT debian DOT olsr> Organization: Individuum auf blauem Planet X-Mailer: Claws Mail 3.13.2 (GTK+ 2.24.28; x86_64-pc-linux-gnu) MIME-Version: 1.0 Content-Type: text/plain; charset=US-ASCII Content-Transfer-Encoding: 7bit Reply-To: geda-help AT delorie DOT com Errors-To: nobody AT delorie DOT com X-Mailing-List: geda-help AT delorie DOT com X-Unsubscribes-To: listserv AT delorie DOT com Precedence: bulk Ah, i see. i have connected a line from GND.sym direct to one of the GND-Pins and the other GND-Pin works also. It is a bug? I broke my head.... Thanks for helping me. Am Tue, 23 Feb 2016 10:20:16 +0000 schrieb "Peter Clifton (petercjclifton AT googlemail DOT com) [via geda-help AT delorie DOT com]" : > Sorry I'm not currently able to check this out, but I recall that > gnetlist has (in the past, and possibly currently), not worked > properly in the case where only IO symbols with net=....:1 attributes > (but no actual components). > > My recollection is not that clear, but try adding a dummy component > (perhaps a resistor), with one pin connected on your schematic where > you join PGND and your IO sym. Don't need to give it a footprint > (but you will probably get complaints from pcb about the missing > component). > > If this makes the connection appear in pcb, let us know - and I'll > see if anyone working on the gEDA side of things has any ideas for a > fix, or better work around. > > I have an idea that I've made some boards with netlists that featured > Rdummy1 Rdummy2 etc.... and I think I was working around the same > issue you describe. > > Peter > On 22 Feb 2016 21:03, "Smilie (smilie AT posteo DOT de) [via > geda-help AT delorie DOT com]" wrote: > > > Hallo Guys, > > > > i have a problem with my net or netname-attributes. > > > > I have a connector with some io-1.sym's with attributes like this: > > net="abcd:1". > > Than i have a PGND.sym connected to the other io-1.sym's. > > They have also the attribs net="abcd:1". > > > > I wont tho have a connection between the connector and the pgnd but > > there is no connection in pcb. > > > > What is wrong? > > > > Thanks for helping me. > >